MODEL |
VAT-H300-5 |
VAT-H350-12 |
VAT-H350-24 |
OUTPUT |
DC Output |
5V |
12V |
24V |
Rated Current |
5.00-5.05V |
29.17A |
14.5A |
Current Range Note 1 |
60A |
0~29.17A |
0~14.5A |
Ripple and Noise
Note 2 |
0~65°C |
200mV |
180mV |
240mV |
Voltage ADJ. Range |
±10% of rated output voltage |
Voltage Accuracy |
±2.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±2.0% |
±1.0% |
±1.0% |
Set-up Time |
<2.0S (220Vac input, Full load) |
Hold up Time |
>10mS(220Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
176Vac~264Vac |
Frequency Range |
47Hz~63Hz |
Efficiency ( Typical) |
79.5%(220Vac input) |
83.5%(220Vac input) |
86%(220Vac input) |
AC Current (max.) |
4A |
Inrush Current (Typical) |
50A@220Vac Cold start |
Leakage Current |
Input-output:<0.25mA Input-PG:<0.5mA |
PROTECTION |
Over Power |
105%~150% of rated output power, auto recovery |
Over Current |
105%~150% of rated output current, auto recovery |
Over Voltage |
105%~150% of rated output voltage, auto recovery |
Shorted Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-40¢J~65¢J; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-40¢J~85¢J; 10%~95%RH No condensing |
SAFETY &EMC
Note 3 |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
/ |
Harmonic Current |
/ |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
199X99X50mm |
Packing |
12pcs/carton GW:11.40KGS |
Cooling method |
Fored air cooling
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
4. If you need fixture A or B for install purpose,please contact our sales. |