MODEL |
PS-60-3.3 |
PS-60-5 |
PS-60-12 |
PS-60-15 |
PS-60-24 |
PS-60-48 |
OUTPUT |
DC Output |
3.3V |
5.0V |
12.0V |
15.0V |
24.0V |
48.0V |
Rated Current |
8.0A |
8.0A |
4.5A |
3.6A |
2.5 A |
1.25A |
Ripple and Noise
Note 2 |
0~70°C |
80mV |
80mV |
120mV |
150mV |
240mV |
240mV |
-25°C~0°C |
200mV |
200mV |
300mV |
360mV |
360mV |
600mV |
Voltage ADJ. Range |
-5.0%~+10% of rated output voltage |
Voltage Accuracy |
±3.0% |
Line Regulation |
±0.5% |
Load Regulation |
±2.0% |
Set-up Time |
≤1.0S (230Vac input, Full load) |
Hold up Time |
≥20mS(230Vac input, Full load) |
Temperature Coefficient |
กำ0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range Note 3 |
90Vac~264Vac |
Frequency Range |
47Hz-63Hz |
Efficiency ( Typical) |
75% |
81% |
84% |
84% |
86% |
87% |
AC Current (max.) |
<1.5A |
Inrush Current (Typical) |
<30A@120Vac <60A@230Vac Cold start |
Leakage Current |
<0.25mA |
PROTECTION |
Over Load |
105%~180% of rated output current, hi-cup mode,auto recovery |
Over Voltage |
110%~150% of rated output voltage, Constant voltage, |
Shorted Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20°C~70°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-40°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 4) |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA . |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,-3 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
101.6X50.8X30mm |
Packing |
60PCS/CTN, G.W:12kgs |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. AC input range selected with switching.
4. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |