HOME > Products > AC DC Switching Power Supply > AC DC Open Frame Type Single Output: Switching Power Supply > PS-60

Quantity:
PS-60

Features:

  • Universal AC input/ Full range
  • High Efficiency, low power consumption
  • Output protections: SCP/OVP/ OLP
  • Wide operating ambient temperature (-20°C~70°C)
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
  • 3 year warranty

    Specifications:

    MODEL

    PS-60-3.3

    PS-60-5

    PS-60-12

    PS-60-15

    PS-60-24

    PS-60-48

    OUTPUT

    DC Output

    3.3V

    5.0V

    12.0V

    15.0V

    24.0V

    48.0V

    Rated Current

    8.0A

    8.0A

    4.5A

    3.6A

    2.5 A

    1.25A

    Ripple and Noise 

    Note 2

    0~70°C

    80mV

    80mV

    120mV

    150mV

    240mV

    240mV

    -25°C~0°C

    200mV

    200mV

    300mV

    360mV

    360mV

    600mV

    Voltage ADJ.  Range

    -5.0%~+10% of rated output voltage

    Voltage Accuracy

    ±3.0%

    Line Regulation

    ±0.5%

    Load Regulation

    ±2.0%

    Set-up Time

    1.0S (230Vac input, Full load)

    Hold up Time

    20mS(230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range   Note 3

    90Vac~264Vac

    Frequency Range

    47Hz-63Hz

    Efficiency ( Typical)

    75%

    81%

    84%

    84%

    86%

    87%

    AC Current (max.)

    <1.5A

    Inrush Current (Typical)

    <30A@120Vac    <60A@230Vac      Cold start

    Leakage Current

    <0.25mA

    PROTECTION

    Over Load

    105%~180% of rated output current, hi-cup mode,auto recovery

    Over Voltage

    110%~150% of rated output voltage, Constant voltage,

    Shorted Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -20°C~70°C;  20%~90%RH  No condensing

    Storage Temp. & Hum.

    -40°C~85°C;  10%~95%RH  No condensing

    SAFETY &EMC  

    (Note 4)

    Safety Standards

    GB4943-2001; EN60950-1: 2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; 10mA .

    Isolation Resistance

    100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022(CISPR22)ClassB

    Harmonic Current

    Compliance to EN61000-3-2,-3

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    101.6X50.8X30mm

    Packing

    60PCS/CTN, G.W:12kgs

    Cooling method

    Cooling by free air convection

     

    NOTE

    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
    3.  AC input range selected with switching.
    4.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.