Description:
1. Industry standard footprint: 2.28" x 1.45" x 0.37" ( 57.9 x 36.8 x 9.3mm3).
2. Typical efficiency: 90%.
3. Wide input voltage: 36 - 75V.
4. Single output: 2.5V, 3.3V, 5V.
5. Remote control.
6. Trim and sense function.
7. Input under-voltage shutdown.
8. Output over-current protection.
9. Output over-voltage protection.
10. Output short-circuit protection.
11. Over-temperature protection.
12. No minimum load requirement.
13. Basic isolation.
Specification:
1. Electrical specifications:
(1) Input range: 36 - 75Vdc.
(2) Input under-voltage shutdown: 32 - 34 Vdc.
(3) Output voltage setpoint accuracy:± 1.5% Vo max.
(4) Output voltage adjust: 90% to 110% Vo.
(5) Line regulation: 0.2% Vo max.
(6) Load regulation: 0.2% Vo max.
(7) Short-circuit protection: continuous, auto-recovery ( or latch off).
(8) Over-current protection: > 110% Io, auto-recovery ( or latch off).
(9) Over-voltage protection: > 110% Vo, latch off ( or auto-recovery).
(10) Ripple and noise: < 100 mVpp max.
(11) Transient response: recovery < 150uS typical 150mV typical
( 25% step load change from 50% Io).
(12) DI / DT: 1A / 10uS.
2. Environment.
(1) Operating ambient temperature range: -40°C to 55°C.
(2) Operating case temperature range: -40°C to 100°C.
(3) Storage temperature: -55°C to 125°C.
(4) Temp. coefficient: < ± 0.02%/ °C.
(5) MTBF: > 2 million hrs.
3. Control.
(1) Control voltage.
(2) Positive logic:
High = on: 3.5 to 10 Vdc.
Low = off: - 0.7 to 0.8 Vdc.
(3) Negtive logic:
Low = on: - 0.7 to 0.8 Vdc.
High = off: 3.5 to 10 Vdc.
(4) Control: 2mA max. ( for positive logic), 4mA max. ( for negative logic).
|