MODEL |
PDF-320-5 |
PDF-320-7.5 |
PDF-320-12 |
PDF-320-24 |
PDF-320-32 |
PDF-320-36 |
PDF-320-48 |
OUTPUT |
DC Output |
5.0V |
7.5V |
12V |
24V |
32V |
36V |
48V |
Rated Current |
60A |
40A |
25A |
13A |
10A |
8.8A |
6.7A |
Current Range Note 1 |
0~60A |
0~40A |
0~25A |
0~13A |
0~10A |
0~8.8A |
0~6.7A |
Ripple and Noise
Note 2 |
0-65°C |
150mV |
150mV |
150mV |
150mV |
200mV |
200mV |
240mV |
-20°C |
180mV |
150mV |
150mV |
150mV |
200mV |
200mV |
240mV |
Voltage ADJ. Range |
±10% of rated output voltage |
Voltage Accuracy |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.3% |
±0.5% |
±0.2% |
±0.2% |
±0.2% |
Load Regulation |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Set-up Time |
<1.2S (230Vac input, Full load), <2.5S (115Vac input, Full load) |
Hold up Time |
5V>14mS 7.5V/15V/24V/32V/36V/48V¡Ö16mS/ (230Vac input, Full load) |
Temperature Coefficient |
±0.05%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
88Vac~264Vac |
Frequency Range |
47Hz--63Hz |
Power Factor(Typical) |
PF>0.98/115VAC PF>0.93/230VAC |
Efficiency ( Typical) |
79% |
83% |
86% |
87% |
87% |
87% |
88% |
AC Current (max.) |
4.0A |
Inrush Current (Typical) |
<45A@230Vac <23A@115Vac Cold start |
Leakage Current |
Input-output: ≤0.1mA Input-PG: ≤0.75mA |
PROTECTION |
Over Load |
105%~135% of rated output current, hiccup mode,auto recovery |
Over Temperture |
85°C+5(detect on heats°Cink of power transistor);shut down,auto recovery after the temperature goes down |
Over Voltage |
110%~150% of rated voltage; Shut down |
Short Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20°C~65°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-40°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
GB4943-2001; EN60950-1¡G2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVac;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
226.5X115X50mm |
Packing |
10PCS/CTN, GW:11.6kgs |
Cooling method |
Fored air cooling(Built-in fan) |
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |