MODEL |
PDF-200-5 |
PDF-200-12 |
PDF-200-15 |
PDF-200-24 |
PDF-200-48 |
OUTPUT |
DC Output |
5.0V |
12V |
15V |
24V |
48V |
Rated Current |
40A |
16.7A |
13.4A |
8.4A |
4.2A |
Current Range Note 1 |
0~40A |
0~16.7A |
0~13.4A |
0~8.4A |
0~4.2A |
Ripple and Noise Note 2 |
100mV |
100mV |
100mV |
150mV |
250mV |
Voltage ADJ. Range |
4.3V~6.0V |
11.4V~13.2V |
14.3V~16.5V> |
22.8V~26.4V |
45.6V~52.8V |
Voltage Accuracy |
±2.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Set-up Time |
<2.0S (230Vac input, Full load) |
Hold up Time |
>20mS(230Vac input, Full load) |
Temperature Coefficient |
±0.05%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
85Vac~264Vac |
Frequency Range |
47Hz--63Hz |
Power Factor(Typical) |
PF¡Ö0.98/115VAC PF¡Ö0.93/230VAC |
Efficiency ( Typical) |
83% |
79% |
82% |
82% |
83% |
AC Current (max.) |
3.5A/115VAC 1.7A/230VAC |
Inrush Current (Typical) |
50A@230Vac Cold start |
Leakage Current |
Input-output:<0.25mA Input-PG:<3.5mA |
PROTECTION |
Over Load |
105%~140% of rated output current, Hiccup mode,auto recovery |
Over Temperature |
95°C±5°C(detect on heatsink of power transistor);shut down,auto recover after the temperature goes down |
Over Voltage |
105%~150% of rated output voltage, shut down |
Short Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-10°C~60°C; 20%~90%RH No condensing(refer to the derating curve) |
Storage Temp. & Hum. |
-20°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
UL60950-1; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
199X99X50mm |
Packing |
12PCS/CTN, G.W: 11.3kgs |
Cooling method |
Cooling by forced air (built-in DC fan) |
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |