HOME > Products > AC DC Switching Power Supply > AC DC Enclosed Mini-Size Single Output: Switching Power Supply > PDF-150

Quantity:
PDF-150
Features:
  • niversal AC input/ Full range
  • Built-in active PFC function,PF>0.93
  • High Efficiency, and High reliability
  • Output protections: OLP/OVP/SCP
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
  • 3 years warranty

    Specification:

    MODEL

    PDF-150-5

    PDF-150-12

    PDF-150-15

    PDF-150-24

    PDF-150-36

    PDF-150-48

    OUTPUT

    DC Output

    5.0V

    12V

    15V

    24V

    36V

    48V

    Rated Current

    30A

    12.5A

    10.0A

    6.3A

    4.1A

    3.2A

    Current Range     Note 1

    0~30A

    0~12.5A

    0~10A

    0~6.3A

    0~4.1A

    0~3.2A

    Ripple and Noise   Note 2

    100mV

    100Mv

    100mV

    150mV

    240mV

    240mV

    Voltage ADJ.  Range

    4.0V~6.0V

    10.0V~14.0V

    12.0V~18.0V

    20.0V~28.0V

    32V~40V

    42.0V~54V

    Voltage Accuracy

    ±2.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Line Regulation

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    Load Regulation

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Set-up Time

    <2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load)

    Hold up Time

    >20mS(115Vac/230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range  

    85Vac~264Vac

    Frequency Range

    47Hz--63Hz

    Power Factor(Typical)

    PF>0.98/115VAC    PF>0.94/230VAC

    Efficiency ( Typical)

    115Vac input

    80%

    82%/230Vac

    83%

    83%

    83%

    83%

    84%

    230Vac input

    82%

    86%

    86%

    86%

    86%

    87%

    AC Current (max.)

    2.0A

    Inrush Current (Typical)

    30A@115Vac; 60A@230Vac      Cold start

    Leakage Current

    Input-output:<0.25mA     Input-PG:<3.5mA

    PROTECTION

    Over Load

    105%~150% of rated output current, hiccup mode, auto recovery

    Over Voltage

    110%~150% of rated output voltage, shut dow(5V) 110%~130% of rated output voltage, shut dow(48V)

    110%~140% of rated output voltage, shut dow(12V/15V/24V) ,

    Short Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -10°C~60°C;  20%~90%RH  No condensing;please( refer to the derating curve)

    Storage Temp. & Hum.

    -20°C~85°C;  10%~95%RH  No condensing

    SAFETY &EMC  

    (Note3)

    Safety Standards

    UL60950-1; EN60950-1: 2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.

    Isolation Resistance

    ≥100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022 ClassB

    Harmonic Current

    Compliance to EN61000-3-2,17625.1-2003

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    194X99X50mm

    Packing

    20PCS/CTN.  G.W:15.2kgs

    Cooling method

    Cooling by free air convection

     

    NOTE

    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.