MODEL |
PDF-100-5 |
PDF-100-12 |
PDF-100-15 |
PDF-100-24 |
PDF-100-48 |
OUTPUT |
DC Output |
5.0V |
12V |
15V |
24V |
48V |
Rated Current |
20A |
8.5A |
6.7A |
4.2A |
2.15A |
Current Range Note 1 |
0~20A |
0~8.5A |
0~6.7A |
0~4.2A |
0~2.15A |
Ripple and Noise Note 2 |
100mV |
100mV |
100mV |
150mV |
250mV |
Voltage ADJ. Range |
4.0V~5.9V |
10V~14V |
13.5V~17.0V |
20V~28V |
43V~55V |
Voltage Accuracy |
±2.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Set-up Time |
<2.0S (230Vac input, Full load) |
Hold up Time |
>20mS(230Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
85Vac~264Vac 120~370VDC |
Frequency Range |
47Hz--63Hz |
Power Factor(Typical) |
PF>0.98/115VAC PF>0.93/230VAC |
Efficiency ( Typical) |
120Vac input |
78% |
83% |
83% |
83% |
84% |
230Vac input |
80% |
85% |
85% |
86% |
87% |
AC Current (max.) |
1.7A/115VAC 0.8A/230VAC |
Inrush Current (Typical) |
50A@230Vac Cold start |
Leakage Current |
Input-output:<0.25mA Input-PG:<3.5mA |
PROTECTION |
Over Load |
105%~150% of rated output current, hiccup mode, auto recovery |
Over Voltage |
110%~150% of rated output voltage, shut down |
Short Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-10°C~60°C; 20%~90%RH No condensing(refer to the derating curve) |
Storage Temp. & Hum. |
-20°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
UL60950-1; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
194X99X50mm |
Packing |
20PCS/CTN. G.W: 15.2kgs |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |