HOME > Products > AC DC Switching Power Supply > AC DC Enclosed Mini-Size Single Output: Switching Power Supply > PD-60

Quantity:
PD-60
Features:
  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: OLP/OVP/SCP
  • Wide operating ambient temperature (-20°C~70°C)
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
  • 3 years warranty

    Specification:

    MODEL

    PD-60-5

    PD-60-12

    PD-60-15

    PD-60-24

    PD-60-48

    OUTPUT

    DC Output

    5.0V

    12.0V

    15.0V

    24.0V

    48.0V

    Rated Current

    12A

    5A

    4.0A

    2.5A

    1.25A

    Current Range     Note 1

    0~12A

    0~5.0A

    0~4.0A

    0~2.5A

    0~1.25A

    Ripple and Noise 

    Note 2

    0~55°C

    50mV

    120mV

    120mV

    120mV

    240mV

    -10°C

    100mV

    120mV

    120mV

    120mV

    240 mV

    Voltage ADJ.  Range

    4.2V-5.8V

    10.8V-13.2V

    13.5V-16.5V

    21.5V-25.8V

    45V-52V

    Voltage Accuracy

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    Line Regulation

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    Load Regulation

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    Set-up Time

    <2S (115Vac input, Full load); <1.0S (230Vac input, Full load)

    Hold up Time

    >10mS(115Vac input, Full load);>20mS(230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/¢J

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range  

    88Vac~264Vac

    Frequency Range

    47Hz--63Hz

    Efficiency ( Typical)

    83%

    80%

    80%

    80%

    83%

    AC Current (max.)

    1.6A

    1.6A

    2.5A

    1.5A

    1.5A

    1.45A

    Inrush Current (Typical)

    20A@115Vac    40A@230Vac      Cold start

    Leakage Current

    <0.25Ma@115Vac     <3.5mA@230Vac

    PROTECTION

    Over Load

    105%~150% of rated output current, hiccup mode, auto recovery

    Over Voltage

    110%~125% of rated output voltage, shut down(48V)  12%~150 of rated output voltage, shut down(5V),

    110%~140% of rated output voltage, shut down(15V,24V),

    110%~133% of rated output voltage, shut down(12V),

    Short Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -20°C~70°C;  20%~90%RH  No condensing((refer to the derating curve)

    Storage Temp. & Hum.

    -40°C~85°C;  10%~95%RH  No condensing

    SAFETY &EMC  

    (Note 3)

    Safety Standards

    UL60950-1; EN60950-1:2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA.

    Isolation Resistance

    ≥100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022(CISPR22)ClassB

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25¢J, Full load)

    Dimension  (L*W*H)

    129x98X38mm

    Packing

    30PCS/CTN, G.W:14.2kgs

    Cooling method

    Cooling by free air convection

     

    NOTE


    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.