HOME > Products > Switch Power Supply Design > PD-25 Switch Power Supply Design

Quantity:
PD-25 Switch Power Supply Design

Features:

  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: OLP/OVP/SCP
  • Wide operating ambient temperature (-20°C~70°C)
  • All using 105¢J long life electrolytic capacitors.
  • 100% full load burn-in test
  • 3 years warranty

    Specification:

    MODEL

    PD-25-S3.3

    PD-25-S5

    PD-25-S12

    PD-25-S15

    PD-25-S24

    OUTPUT

    DC Output

    3.3V

    5V

    12V

    15V

    24V

    Rated Current

    6A

    5A

    2.1A

    1.7 A

    1.1A

    Current Range     Note 1

    0~6A

    0~5A

    0~2.1A

    0~1.7A

    0~1.1A

    Ripple and Noise 

    Note 2

    0~70°C

    80mV

    80mV

    120mV

    120mV

    120mV

    -20~0°C

    240 mV

    Voltage ADJ.  Range

    ±10% of rated output voltage

    Voltage Accuracy

    ±2.0%

    ±2.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Line Regulation

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    Load Regulation

    ±2.0%

    ±2.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Set-up Time

    <2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load)

    Hold up Time

    >14mS(115Vac input, Full load); > 30mS(230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    < 5.0%

    INPUT

    Voltage Range  

    88Vac~264Vac

    Frequency Range

    47Hz~63Hz

    Efficiency ( Typical)

    70%(115Vacinput)

    75%(115Vacinput)

    80%(115Vacinput)

    81%(115Vacinput)

    83%(115Vacinput)

    71%(230Vacinput)

    77%(230Vacinput)

    82%(230Vacinput)

    83%(230Vacinput)

    84%(230Vacinput)

    AC Current (max.)

    0.7A

    0.7A

    2.5A

    0.35A

    0.7A

    0.7A

    Inrush Current (Typical)

    20A@115Vac    40A@230Vac      Cold start

    Leakage Current

    Input-output:<0.25mA     Input-PG:<0.75mA

    PROTECTION

    Over Load

    105%~150% of rated output current, hiccup mode,auto recovery

    Over Voltage

    105%~150% of rated output voltage, Constant Voltage

    Short Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -20°C~70°C;  20%~90%RH  No condensing((refer to the derating curve)

    Storage Temp. & Hum.

    -40°C~85°C;  10%~95%RH  No condensing

    SAFETY &EMC

    Note 3

    Safety Standards

    UL60950-1; EN60950-1: 2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

    Isolation Resistance

    100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022(CISPR22) ClassB

    Harmonic Current

    Compliance to EN61000-3-2,-3

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    79X51X28mm

    Packing

    48PCS/CTN,  G.W:10.4kgs

    Cooling method

    Cooling by free air convection

    NOTE

    1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.  Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.