MODEL |
PD-20-5 |
PD-20-12 |
PD-20-15 |
PD-20-24 |
PD-20-48 |
OUTPUT |
DC Output |
5V |
12V |
15V |
24V |
48V |
Rated Current |
4A |
1.67A |
1.34A |
0.84A |
0.42A |
Current Range Note 1 |
0~4A |
0~1.67A |
0~1.34A |
0~0.84A |
0~0.42A |
Ripple and Noise
Note 2 |
0~50°C |
50mV |
120mV |
100mV |
100mV |
100mV |
-10~0°C |
75mV |
120mV |
100mV |
100mV |
100mV |
Voltage ADJ. Range |
±10% of rated output voltage |
Voltage Accuracy |
±2.0% |
±2.0% |
2.0% |
±2.0% |
±2.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
Set-up Time |
<2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load) |
Hold up Time |
>10mS(115Vac input, Full load); >20mS(230Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
85Vac~264Vac |
Frequency Range |
47Hz~63Hz |
Efficiency ( Typical) |
115Vacinput |
72% |
78% |
80% |
78% |
78% |
230Vacinput |
72% |
78% |
80% |
76% |
78% |
AC Current (max.) |
0.5A
2.5A |
0.5A |
0.5A |
0.5A |
0.5A |
Inrush Current (Typical) |
Cold start 20A@115Vac 40A@230Vac |
Leakage Current |
Input-output:<0.35mA Input-PG:<0.75mA |
PROTECTION |
Over Load |
105%~150% rated output power; Hiccup mode, auto recovery |
Over Voltage |
110%~140% of rated output voltage, Constant Voltage. |
Short Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20°C~60°C; 20%~90%RH No condensing(refer to the derating curve) |
Storage Temp. & Hum. |
-40°C~85°C; 10%~95%RH No condensing |
SAFETY & EMC Note 3 |
Safety Standards |
UL60950-1; EN60950-1ĄG2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
89X51X20mm |
Packing |
60PCS/CTN, G.W:7.6kgs |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |