HOME > Products > AC DC Switching Power Supply > AC DC Open Frame Type Single Output: Switching Power Supply > PD-20

Quantity:
PD-20

Features:

  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Ultra-miniature size, low profile
  • Output protections: OLP/OVP/SCP
  • Wide operating ambient temperature (-20°C~60°C)
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
  • 3 years warranty

    Specifications:

    MODEL

    PD-20-5

    PD-20-12

    PD-20-15

    PD-20-24

    PD-20-48

    OUTPUT

    DC Output

    5V

    12V

    15V

    24V

    48V

    Rated Current

    4A

    1.67A

    1.34A

    0.84A

    0.42A

    Current Range     Note 1

    0~4A

    0~1.67A

    0~1.34A

    0~0.84A

    0~0.42A

    Ripple and Noise 

    Note 2

    0~50°C

    50mV

    120mV

    100mV

    100mV

    100mV

    -10~0°C

    75mV

    120mV

    100mV

    100mV

    100mV

    Voltage ADJ.  Range

    ±10% of rated output voltage

    Voltage Accuracy

    ±2.0%

    ±2.0%

    2.0%

    ±2.0%

    ±2.0%

    Line Regulation

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    ±0.5%

    Load Regulation

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    Set-up Time

    <2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load)

    Hold up Time

    >10mS(115Vac input, Full load); >20mS(230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range  

    85Vac~264Vac

    Frequency Range

    47Hz~63Hz

    Efficiency ( Typical)

    115Vacinput

    72%

    78%

    80%

    78%

    78%

    230Vacinput

    72%

    78%

    80%

    76%

    78%

    AC Current (max.)

    0.5A

    2.5A

    0.5A

    0.5A

    0.5A

    0.5A

    Inrush Current (Typical)

    Cold start  20A@115Vac    40A@230Vac     

    Leakage Current

    Input-output:<0.35mA     Input-PG:<0.75mA

    PROTECTION

    Over Load

    105%~150% rated output power; Hiccup mode, auto recovery

    Over Voltage

    110%~140% of rated output voltage, Constant Voltage. 

    Short Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -20°C~60°C;  20%~90%RH  No condensing(refer to the derating curve)

    Storage Temp. & Hum.

    -40°C~85°C;  10%~95%RH  No condensing

    SAFETY & EMC Note 3

    Safety Standards

    UL60950-1; EN60950-1ĄG2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA.

    Isolation Resistance

    100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022(CISPR22)ClassB

    Harmonic Current

    Compliance to EN61000-3-2,17625.1-2003

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    89X51X20mm

    Packing

    60PCS/CTN,  G.W:7.6kgs

    Cooling method

    Cooling by free air convection

     

    NOTE

    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.