MODEL |
PD-150-5 |
PD-150-12 |
PD-150-15 |
PD-150-24 |
PD-150-48 |
OUTPUT |
DC Output |
5V |
12V |
15V |
24V |
48V |
Rated Current |
26A |
12.5A |
10A |
6.5 A |
3.3A |
Current Range Note 1 |
0~26A |
0~12.5A |
0~10A |
0~6.5A |
0~3.3A |
Ripple and Noise
Note 2 |
0~70°C |
80mV |
120mV |
120mV |
120mV |
200mV |
-20°C |
100mV |
150 mV |
180 mV |
150 mV |
300 mV |
Voltage ADJ. Range |
4.2V-6.0V |
10.0V-14.0V |
13.0V-17.0V |
21.0V-28.0V |
43.0V-54.0V |
Voltage Accuracy |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation/ |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Set-up Time |
<2.0S (115Vac input, Full load); <1.0S (230Vac input, Full load) |
Hold up Time |
>10mS(115Vac input, Full load); >20mS(230Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C(0°C~50°C)
|
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range Note 3 |
88Vac/176Vac~132Vac/264Vac |
Frequency Range |
47Hz~63Hz |
Efficiency ( Typical) |
115Vac input |
78% |
83% |
83% |
84% |
85% |
230Vac input |
79% |
83% |
84% |
85% |
86% |
AC Current (max.) |
≤3.5A/2.0A |
Inrush Current (Typical) |
20A@115Vac 40A@230Vac Cold start |
Leakage Current |
<0.25mA/115Vac <2.0mA/230Vac |
PROTECTION |
Over Load |
105%~150% of rated output current , hiccup mode,auto recovery |
Over Voltage |
120%~150% of rated output voltage, shut down |
Short Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20¢X°C~70°C; 20%~90%RH No condensing(refer to the derating curve) |
Storage Temp. & Hum. |
-40°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 4) |
Safety Standards |
UL60950-1; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,-3 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
199X98X38mm |
Packing |
20PCS/CTN, G.W:15kgs |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. AC input range selected by switch.
4. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |