MODEL |
MGS-H60T5+24+12 |
OUTPUT |
Ouput Number |
V1 |
V2 |
V3 |
DC Output |
5.0V |
24.0V |
12.0V |
Rated Current |
5.0A |
2.0A |
1.0A |
Current Range Note 1 |
0.25~5.0A |
0.1~2.0A |
0.05~1.0A |
Ripple and Noise Note 2 |
50mV |
200mV |
120mV |
Voltage ADJ. Range |
V1:4.4-5.6V |
Voltage Accuracy |
±2.0% |
±5.0%(0.5<I1:I2<3) |
±5.0%(1.0<I1:I3<20) |
Line Regulation |
±0.5% |
±1.0% |
±1.0% |
Load Regulation |
±1.0% |
±5.0%(0.5<I1:I2<3) |
±5.0%(1.0<I1:I2<20) |
Set-up Time |
<1.0S (220Vac input, Full load) |
Hold up Time |
>20mS(220Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
176Vac~265Vac |
Frequency Range |
47Hz-63Hz |
Efficiency ( Typical) |
75% |
AC Current (max.) |
0.8A |
Inrush Current (Typical) |
40A@220Vac Cold start |
Leakage Current |
Primary--PG:<0.25mA; Secondary-PG: <3.5mA |
PROTECTION |
Over Power |
V2:120%~350% of rated output current, auto recovery |
Over Current |
V2:3A-8A@ V1/2A,V3/0.5A, auto recovery |
Over Voltage |
V1:115%~150% of rated output voltage, Shut down |
Shorted Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb.Temp.& Hum. |
0°C~50°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-20°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac;≤10mA.Primary-PG:2.0KVac; ≤10mA.Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,ClassA |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
160X98X38mm |
Packing |
20PCS/CTN, 13.6Kgs |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
4. Burn in test for +5V/4A,+24V/1A, +12/0.5A. |