HOME > Products > AC DC Switching Power Supply > AC DC Enclosed Standard: Switching Power Supplies > GZM-U25S

Quantity:
GZM-U25S
Features:
  • Universal AC input/ Full range
  • High Efficiency, and High reliability
  • Output protections: SCP/OVP/OPP/OLP
  • Wide operating ambient temperature (-10°C~50°C)
  • All using 105°C long life electrolytic capacitors.
  • 100% full load burn-in test
  • 2 year warranty

    Specification:

    MODEL

    GZM-U25S5

    GZM-U25S12

    GZM-U25S15

    GZM-U25S24

    GZM-U25S48

    OUTPUT

    DC Output

    5.0V

    12.0V

    15.0V

    24.0V

    48.0V

    Rated Current

    5.00A

    2.10A

    1.70A

    1.10A

    0.55A

    Current Range     Note 1

    0~5.0A

    0~2.10A

    0~1.70A

    0~1.10A

    0~0.55A

    Ripple and Noise 

    Note 2

    0~50°C

    50mV

    50mV

    50mV

    50mV

    50mV

    -10°C

    100mV

    100mV

    100mV

    150mV

    150 mV

    Voltage ADJ.  Range

    4.5V-5.5V

    11V-13V

    13V-16.5V

    21.5V-25.5V

    44V-52V

    Voltage Accuracy

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    Line Regulation

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Load Regulation

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    ±2.0%

    Set-up Time

    <3.0S (120Vac input, Full load); < 1.5S (220Vac input, Full load)

    Hold up Time

    >10mS(120Vac input, Full load); >20mS(220Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range  

    90Vac~264Vac

    Frequency Range

    47Hz--63Hz

    Efficiency ( Typical)

    76%

    78%

    80%

    82%

    84%

    AC Current (max.)

    0.7A

    Inrush Current (Typical)

    20A@120Vac    40A@220Vac      Cold start

    Leakage Current

    Primary-Secondary: <0.25mA     Primary-Gvround: <3.5mA

    PROTECTION

    Over Power

    105%~150% of rated output current, auto recovery

    Over Current

    105%~150% of rated output current, auto recovery

    Over Voltage

    105%~150% of rated output voltage, auto recovery

    Shorted Circuit

    Long-term mode, auto recovery

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -10°C~50°C;  20%~90%RH  No condensing

    Storage Temp. & Hum.

    -40°C~85°C;  10%~95%RH  No condensing

    SAFETY &EMC  

    (Note 3)

    Safety Standards

    GB4943-2001; EN60950-1: 2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVdc;10mA.

    Isolation Resistance

    100M ohms

    EMI Conduction&Radiation

    Compliance to EN55022(CISPR22)ClassB

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    143X59X38mm

    Cooling method

    Cooling by free air convection

     

    NOTE

    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.