MODEL |
GZM-U25S5 |
GZM-U25S12 |
GZM-U25S15 |
GZM-U25S24 |
GZM-U25S48 |
OUTPUT |
DC Output |
5.0V |
12.0V |
15.0V |
24.0V |
48.0V |
Rated Current |
5.00A |
2.10A |
1.70A |
1.10A |
0.55A |
Current Range Note 1 |
0~5.0A |
0~2.10A |
0~1.70A |
0~1.10A |
0~0.55A |
Ripple and Noise
Note 2 |
0~50°C |
50mV |
50mV |
50mV |
50mV |
50mV |
-10°C |
100mV |
100mV |
100mV |
150mV |
150 mV |
Voltage ADJ. Range |
4.5V-5.5V |
11V-13V |
13V-16.5V |
21.5V-25.5V |
44V-52V |
Voltage Accuracy |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
Line Regulation |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Load Regulation |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
Set-up Time |
<3.0S (120Vac input, Full load); < 1.5S (220Vac input, Full load) |
Hold up Time |
>10mS(120Vac input, Full load); >20mS(220Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
90Vac~264Vac |
Frequency Range |
47Hz--63Hz |
Efficiency ( Typical) |
76% |
78% |
80% |
82% |
84% |
AC Current (max.) |
0.7A |
Inrush Current (Typical) |
20A@120Vac 40A@220Vac Cold start |
Leakage Current |
Primary-Secondary: <0.25mA Primary-Gvround: <3.5mA |
PROTECTION |
Over Power |
105%~150% of rated output current, auto recovery |
Over Current |
105%~150% of rated output current, auto recovery |
Over Voltage |
105%~150% of rated output voltage, auto recovery |
Shorted Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-10°C~50°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-40°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVdc;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
143X59X38mm |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. |