MODEL |
GZM-H100D5+12 |
OUTPUT |
Ouput Number |
V1 |
V2 |
DC Output |
5.0V |
12.0V |
Rated Current |
10.0A |
4.0A |
Current Range Note 1 |
0 ~10.0A |
0 ~4.0A |
Ripple and Noise Note 2 |
0~65°C |
120mV |
120mV |
-25~0°C |
240mV |
240mV |
Voltage Accuracy |
±1.0% |
±10.0% |
Line Regulation |
±0.5% |
±1.0% |
Load Regulation |
±3.0% |
±10.0% |
Set-up Time |
<1.0S (220Vac input, Full load) |
Hold up Time |
>20mS(220Vac input, Full load) |
Temperature Coefficient |
±0.03%/°C |
±0.03%/°C |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
176Vac~264Vac |
Frequency Range |
47Hz-63Hz |
Efficiency ( Typical) |
75%@220Vac, |
AC Current (max.) |
2.0A |
Inrush Current (Typical) |
50A@220Vac Cold start |
Leakage Current |
Input-Output: ≤0.25mA Input-PG: ≤3.5mA |
PROTECTION |
Over Power |
105%~150% of rated output current, auto recovery |
Over Current |
V1:110%~220% of rated output current, auto recovery |
Over Voltage |
V1:105%~150% of rated output voltage, auto recovery |
Shorted Circuit |
Long-time; auto recovery |
ENVIRONMENT |
Operating amb.Temp.& Hum. |
-10°C~50°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-30°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 3) |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:1.5KVac;≤10mA.Primary-PG:1.5KVac;≤10mA.Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(GB9254)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,ClassA |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
199X98X40mm |
Cooling method |
Cooling by free air convection
|
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
2. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|