HOME > Products > AC DC Switching Power Supply > AC DC Enclosed Mini-Size Single Output: Switching Power Supply > GPF-U500

Quantity:
GPF-U500
Features:
  • Universal AC input/ Full range
  • Built-in active PFC function,PF>0.95
  • Built-in cooling Fan ON-OFF control
  • Output protections: OLP/OVP/OTP/SCP
  • All using 105°C long life electrolytic capacitors.
  • Build-in remote sense function
  • Build-in remote ON-OFF control
  • 3 years warranty

    Specification:

    MODEL

    GPF-U500S12

    GPF-U500S15

    GPF-U500S24

    GPF-U500S27.5

    GPF-U500S48

    OUTPUT

    DC Output

    12V

    15

    24V

    27.5V

    48V

    Rated Current

    40A

    33A

    20A

    18A

    10A

    Current Range     Note 1

    0~40A

    0~33A

    0~20A

    0~18A

    0~10A

    Ripple and Noise   Note 2

    120mV

    150mV

    240mV

    270mV

    480mV

    Voltage ADJ.  Range

    11.2V-14.2V

    13.0V-17.0V

    21.6V-26.4V

    22.0V-33.0V

    40V-50V

    Voltage Accuracy

    ±3.0%

    ±3.0%

    ±3.0%

    ±3.0%

    ±3.0%

    Line Regulation

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Load Regulation

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    ±1.0%

    Set-up Time

    <4.0S (115Vac input, Full load); <2.0S (230Vac input, Full load)

    Hold up Time

    >20mS(230Vac input, Full load)

    Temperature Coefficient

    ±0.03%/°C

    Overshoot and Undershoot

    <5.0%

    INPUT

    Voltage Range  

    90Vac~264Vac

    Frequency Range

    47Hz~63Hz

    Power Factor(Typical)

    PF>0.99/115VAC    PF>0.95/230VAC

    Efficiency ( Typical)

    115Vacinput

    78%

    80%

    81%

    80%

    82%

    230Vacinput

    82%

    82%

    86%

    86%

    85%

    AC Current (max.)

    7.3A

    2.5A

    7.5A

    7.5A

    7.5A

    7.3A

    Inrush Current (Typical)

    <20A@115Vac    <40A@230Vac      Cold start

    Leakage Current

    Input-output:<0.25mA     Input-PG:<3.5mA

    PROTECTION

    Over Load

    105%~140% of rated output current, constant current limiting,auto recover

    Over Voltage

    115%~150% of rated output voltage, shut down

    Over Temperature

    95°C±5°C(detect on heatsink of power transistor);shut down,auto recover after the temperature goes down

    Fan ON/OFF Control

    Output load>55% rating or inside temperature >65¢J, FAN ON

     

    Function

    Romote ON/OFF Control

    R.C./G: Short = power on; Open=power off

    ENVIRONMENT

    Operating amb. Temp. & Hum.

    -10°C~60°C;  20%~90%RH  No condensing(refer to the derating curve)

    Storage Temp. & Hum.

    -25°C~85°C;  10%~95%RH  No condensing

    SAFETY&EMC Note 3

    Safety Standards

    UL60950-1; EN60950-1: 2006

    Withstand Voltage

    Primary-Secondary:3.0KVac; 10mA .Primary-PG:1.5KVac; 10mA. Secondary-PG:0.5KVDC;10mA.

    Isolation Resistance

    50M ohms

    EMI Conduction&Radiation

    Compliance to EN55022 ClassA

    Harmonic Current

    Compliance to EN61000-3-2,17625.1-2003

    EMS Immunity

    Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level, criteria A

    OTHERS

    MTBF (MIL-HDBK-217F)

    More than 100,000Hrs (25°C, Full load)

    Dimension  (L*W*H)

    170X117X94mm

    Packing

    6PCS/CTN, G.W:13.2kgs

    Cooling method

    Cooling by forced air (built-in DC fan)

    NOTE

    1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
    2.     Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
    3.  The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.