MODEL |
CMG-H150D12G+24 |
CMG-H150D24G+12 |
OUTPUT |
DC Output |
V1 |
12.0V |
24.0V |
V2 |
24.0V |
12.0V |
Rated Current |
V1 |
5A |
6A Note 2 |
V2 |
6A Note 1 |
5A |
Current Range Note 3 |
V1 |
0.5~5.0A |
0~6.0A |
V2 |
0.6~6.0A |
0~5.0A |
Ripple and Noise Note4
0~65°C |
V1 |
120mV |
240mV |
V2 |
240mV |
120mV |
Ripple and Noise
-25~0°C |
V1 |
240mV |
480mV |
V2 |
480mV |
240mV |
Voltage ADJ. Range |
11.4V~12.6V |
22.8V~25.0V |
Voltage Accuracy |
V1 |
±1.0% |
±1.0% |
V2 |
±10.0% |
±10.0% |
Line Regulation |
V1 |
±0.5% |
V2 |
±1.0% |
Load Regulation |
V1 |
±3.0% |
V2 |
±10.0% |
Set-up Time |
<1.0S (230Vac input, Full load) |
Hold up Time |
>20mS(230Vac input, Full load) |
Temperature Coefficient |
±0.03%/¢J |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
176Vac~264Vac |
Frequency Range |
47Hz--63Hz |
Efficiency ( Typical) |
80% |
80% |
AC Current (max.) |
2.0A/176VAC |
Inrush Current (Typical) |
50A@220Vac Cold start |
Leakage Current |
Input-output:<0.25mA Input-PG:<3.5mA |
PROTECTION |
Over Power |
105%~150% of rated output current, auto recovery |
Over Current |
V1 |
110%~220%
Auto recovery |
110%~150%
Auto recovery |
Over Voltage |
V1: 110%~150% of rated output voltage, auto recovery |
Shorted Circuit |
Long-term mode, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-10°C~50°C; 20%~90%RH No condensing |
Storage Temp. & Hum. |
-30°C~85°C; 10%~95%RH No condensing |
SAFETY &EMC
(Note 5) |
Safety Standards |
GB4943-2001; EN60950-1: 2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA.
Secondary-PG:0.5KVDC;≤10mA. Output V1¡XV2: 0.5KVDC;≤10mA. Test time:1 min |
Isolation Resistance |
≥100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25°C, Full load) |
Dimension (L*W*H) |
199X98X40mm |
Packing |
0.75Kg/pcs,20PCS/CTN, 15KGS. |
Cooling method |
Cooling by free air convection
|
NOTE |
1. CMG-H150D12G+24 Total output power can't exceed 150W, Label is marked by the Max current. Recommend the loading is 12V/5A,24V/3.75A.
2. CMG-H150D24G+12Total output power can't exceed 150W, Label is marked by the Max current. Recommend the loading is 24V/5A,12V/3.0A.
3. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature.
4. Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
5. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
|