Untitled Document
Features:
1. Miniature
2. AC input 176-264V only
3. Protections: SCP, OLP, OVP
4. High reliability, low cost
5. 100% full load burn-in test
Specifications:
Input Volt. and Freq.: 176~264 VAC / 47~63 Hz
Inrush current: 40A@230 VAC (cold start)
DC adjustment range:±10% (rated output voltage)
Overload protection: 105%~150% (rated load), auto-recovery
Over voltage protection: 115%~135% (rated output voltage)
Short circuit protection: long term
Setup time: ≤1S@230V
Hold-up time: ≥20mS@230VAC
Withstand voltage:
Input-output: AC 1500V, 1 min
Input-ground: AC 1500V, 1 min
Output-ground: DC 500V, 1 min
Operating ambinet: 0~45°C, 20%~90% RH (non condensing)
Safety standards: EN60950, GB4943
Dimension(LxWxH): 74x68x27 mm
Model No. |
DC Output |
Tol. |
R&N |
Effi. |
GZM-H10D5-5 |
5V |
1.5A |
±3% |
≤50mV |
68% |
-5V |
0.3A |
±3% |
≤50mV |
GZM-H10D5+12R |
5V |
1A |
±3% |
≤50mV |
66% |
12V |
0.4A |
±3% |
≤120mV |
GZM-H10D5+24R |
5V |
1A |
±3% |
≤50mV |
66% |
24V |
0.2A |
±3% |
≤240mV |
|